A disc spring torque limiter works by turning axial spring force into friction torque. Slip torque follows the clamping force, so a repeatable spring load is the whole mechanism. SCHNORR components are used in sliding hubs in conveyor drives, where parallel stacking provides the force in a fixed length and load tolerance decides how tightly the slip point can be held.
Protecting a driveline with a slip point is one of the most elegant uses of a spring, because the spring is not a cushion or a return element. It is the setting itself.
How the mechanism works
In a sliding hub conveyor drive, friction faces are clamped together by a spring stack. Torque transmits through friction until the applied torque exceeds what the clamp can hold, at which point the hub slips instead of something expensive breaking. Raise the axial force and the slip torque rises with it.
Which means the design problem is not really “choose a spring”. It is: hold a known axial force in a fixed installation length, keep it there as the friction faces wear, and keep it repeatable from unit to unit.
Getting the force: parallel stacking
For a slip clutch spring arrangement, parallel stacking is the usual answer. In parallel, forces are additive at the same deflection, so the clamp load rises with almost no change in installation height. Series stacking, where deflections are additive at the same force, is the tool for tolerating movement rather than raising force. Combined arrangements realise various characteristic curves where a particular response is wanted as wear accumulates.
Parallel stacks also carry more internal friction, which contributes to the damping that makes disc springs suited to dynamic duty.
Keeping the force: presetting and a flat working range
Two properties do the work here. Presetting means there is no setting under static loads, so the assembled force does not drift downward over months of standing torque. And the load deflection characteristic can be chosen linear or progressive, which matters because a stack working in a flatter part of its curve loses less force as the friction faces wear down.
Repeatability: this is a load tolerance problem
For a clamping force calculation driving a slip setting, the tolerance that governs is not height, it is force. Disc spring tolerances are defined for overall height, thickness, load and diameter, and it is load tolerance that decides how tightly the slip torque can be held across a production run. If the specification says the clutch must slip within a narrow band, say so at enquiry stage rather than after the first batch is measured.
Guidance, because a slipping joint moves
A torque limiter is, by definition, a joint that sometimes rotates under load. Guidance is not optional:
- A guide element is needed to prevent lateral movement.
- Inside guidance on a bolt or shaft is preferred, though outside guidance is acceptable.
- Guides and abutments should be hardened to a minimum of 60 HRC with a minimum case depth of 0.8 mm where possible.
- The guide surface should be smooth and, if possible, ground.
What to send
For this application the useful inputs are the required slip torque, the friction radius and coefficient you are designing to, the installation space, the expected wear allowance and the acceptable band on slip torque. From those, the stack and the material follow. Standard sizes are in the Product Finder, and where the envelope does not permit a standard part, special sizes and customer specific developments are available.
- SCHNORR components are used in sliding hubs in conveyor drives.
- In a friction torque limiter, slip torque follows the axial clamping force provided by the spring stack.
- Parallel stacking makes forces additive at the same deflection, raising clamp load without adding installation height.
- Series stacking makes deflections additive at the same force, which suits movement rather than force.
- Presetting means there is no setting under static loads, so the clamp force does not drift.
- Disc springs offer linear or progressive load deflection characteristics, and are largely self damping.
- Tolerances are defined for overall height, thickness, load and diameter. Load tolerance governs repeatability of a slip setting.
- A guide element is required, with inside guidance preferred and guides hardened to at least 60 HRC with a minimum case depth of 0.8 mm.
Frequently asked questions
How does a disc spring stack set a torque limit?
The stack clamps friction faces together. Torque transmits through friction until the applied torque exceeds what the clamp force can hold, so slip torque follows the axial spring force.
Should the stack be in series or parallel for a torque limiter?
Parallel. Forces are additive at the same deflection, so clamp load rises with almost no increase in installation height. Series stacking is used to accommodate movement instead.
Will the slip torque drift over time?
Presetting means there is no setting under static loads, so the assembled force holds. A flatter working range on the load deflection curve also reduces the force lost as friction faces wear.
Which tolerance controls how repeatable the slip point is?
Load tolerance. Tolerances are defined for overall height, thickness, load and diameter, and force repeatability is governed by the load band.
What information is needed to design a slip clutch stack?
Required slip torque, the friction radius and coefficient, the installation space, the wear allowance and the acceptable band on slip torque.